Hi-MOD
Compression Fittings Installation
|
Hayn Enterprises, LLC |
Step 1
 |
Wrap a piece of electrician's tape around
the wire and saw to length. A clamp or vice and a file
are useful, but not absolutely necessary. |
 |
Place the body over the wire as shown. |
|
Step 2
 |
Untwist the outer strands by picking
out and twisting in the opposite direction to the lay of the wire. |
 |
Slide the thin end of the cone over the center
core. You can force the cone open with a screwdriver blade
if necessary. |
|
Step 3
 |
Slide the Crown Ring over the
center core with the concave side first.
|

|
There is a hole in the center of the
threaded stud, fork or eye. Push the Crown Ring on with this
part and the core will protrude by the correct amount. |
 |
Twist the outer strands back into position
over the cone. Firmly twist the Crown Ring in the direction
of the lay while you position the outer strands in the slots. |
|
Step 4
 |
Wire Sizes up to 5mm (3/16") require
2 strands per slot (fig.2).
Wire sizes above 5mm (3/16" ) have 1 strand per
slot (fig.3).
|
 |
When all of the outer strands are located the
cone and Crown Ring will remain in place with no assistance. |
 |
Gently twist the body back over the wire, rotating
in the same direction as the lay of the wire. |
|
Step 5
 |
Screw the threaded end fitting
tightly onto the body. DO NOT apply thread
locking solution at this stage. Remove the
end fitting end ensure that the outer strands and Crown Ring
have stayed in position. Secure the fitting's thread with Loctite
262 or some other suitable thread locking solution.
For routine maintenance remove the threaded end fitting, tap
back the body, wash and inspect. Fittings are fully
re-usable unless the cone is distorted.
|
 |
|