WireTeknik
Swaging Instructions
Related
Product Information
Page
Printable Page
|
 |
1. Choose the roller pair of dies that
corresponds to the cable diameter and slip them into
the cogwheel synchronising pins. The arrows on the dies
should always be in swaging direction |
 |
2. Attach the terminal to the attachment
fixture on the drawing arm and adjust the length of
the drawing arm so the roller dies meet on the terminal
shank at the desired position. |
 |
3. Apply just enough hydraulic pressure
so the roller hold the terminal firmly. Then mark and
insert the cable to the bottom of the terminal throat. |
 |
4. Move in to position the transparent
face protector. Apply hydraulic pressure to draw the
terminals between the roller dies. |
 |
5. When they rotates, they will press
the terminal shank onto the wire rope. |
 |
6. Measure the diameter of the terminal
shank after swaging. |
Important Notes. This swager is designed to reduce the terminal shank
to the required diameter in one pass. However variations
in the dimensions of the terminal or cable or material
hardness may make two passes necessary. When swaging solid rod, that a special
swaging compound must be used.
After swaging, wipe off the roller dies and spray the dies and the swager with
a corrosive preventative. |
|